CHONGQING TIANHE--FILTER ENGINEER EXPERT
Product Detail
Steam Flow Meter
Steam Flow Meter 
Detail

1, measuring medium: steam, gas or liquid.

2, the sensing element of the sensor is not directly in contact with the measured medium, stable performance and high reliability.

3, no moving parts in the sensor, the structure is simple and solid, pressure loss, small-dimensional volume expansion, and long service life.

4, wide range of 10: 1 to 15: 1.

5, the vortex flowmeter measurement range: normal operating range, Reynolds is 20,000-7,000,000; the output signal from the liquid temperature, pressure, viscosity and components affected. Measurement possible, Reynolds 8,000-7,000,000.

6. Accuracy class: ± 1.0% liquid indicated value; ± 1.0% gas, indicated value; ± 1.5% steam, indicated value.

7, the output signal: a voltage pulse low: 0-1V; high: more than 4V; 50% duty cycle;

b. Current 4-20mA (three-wire).

8, the power supply voltage: + 12VDC; + 24VDC.

9, medium temperature: Ordinary a.-40 ℃ ~ + 130 ℃; b.-10 ℃ ~ + 250 ℃;

                     High temperature a.-10 ℃ ~ + 350 ℃; b.-10 ℃ ~ + 380 ℃;

10, working pressure: 0-2.5Mpa, clamping flange connection (Note: should the user requirements, can provide additional pressure levels, to be customized).

11, pressure loss: ΔP = ΔP = 1.079 * 10-6 * ρ * v2 (Where: ΔP: Pressure loss kpa; ρ: the measured medium density kg / m3; V: flow rate of the measured medium m / s) .

12, the housing material: carbon steel; stainless steel (1Cr18Ni9Ti).

13, size (pipe diameter) 20,25,32,40,50,65,80,125,150,200,250,300 (greater than DN300 diameter of plug-in).

14, Ambient temperature -25 ℃ ~ + 55 ℃; humidity ≤85% RH.

15, explosion-proof type: intrinsically safe; proof mark; iaIIcT6.